Generac Gp6500 Owner Manual

/ Comments off
Generac Gp6500 Owner Manual

Fuel that is not going to used- even for short periods of time should be treated with fuel stabilizer to slow the rate of deterioration, gumming and varnish formation. Following the fuel stabilizer manufacturer's recommendations, treat the quantity of the fuel remaining in the fuel tank. Open the fuel valve, start and operate the engine for 30 minutes. Close the fuel valve and operate until the engine stops. This circulates treated fuel through lines and carburetor. The fuel can be drained or left in the tank.

Can I convert my portable generator to run on a different fuel besides gasoline? The hourmeter will alert the owner continuously for one hour (of run time) before and until one hour after scheduled maintenance has been reached. This includes oil changes (at 100 hours) or air filter service (at 200 hours). As hours of operation continue to accumulate, the hourmeter will automatically reset itself until the next 100 or 200 hour service interval is reached.

See the Hourmeter section of your owner's manual for additional information. The hourmeter on some generator models have a reset button that allows the operator to move between maintenance intervals and reset intervals by holding the reset button for nine seconds. NOTE: Not all generator models have a reset button. How do I adjust the valve clearance? Portable generator should never be operated inside an enclosed space or contrary to any provision or warning contained in your Owner's Manual.

However, portable generators are intended to be used during extreme weather and for the sensitive electronics on them, it is best if some sort of open covering can be used to protect it from direct rain or snow. Great options would be a car port or boat canopy with four open sides or a tarp hung from a tree. It is very important to provide adequate ventilation for the generator, so any sort of protection should be at least five feet from any side (including the top of the unit) while in use. Additionally, a portable generator should always be stored inside when not in use to prevent unnecessary wear and tear. BE ADVISED, the generator should NEVER be used in any enclosed space including, without limitation, a shed, home, garage, trailer, or vehicle, even if the doors are left open, as this can be a serious fire hazard and carbon monoxide risk. How long can I operate the generator? Does it need a 'break'?

Yes, remove all loads before turning the generator off. First, turn off all appliances, lights and items being powered by the generator. Then, unplug the items from the generator's receptacles and allow the generator to cool. Once you've done this, it is safe to turn the generator off. NEVER turn the generator off while loads are applied. Refer to the Generator Loads section of your owner's manual for complete instruction on adding and removing electrical devices. If the generator is being used, how do I connect or disconnect electrical devices?

Proper grounding of the generator, when used to back-up a building's utility power, will prevent electrical shock in the event of a ground fault condition in the generator or the connected electrical devices. Proper grounding also helps dissipate static electricity which often builds up in ungrounded devices.

Generac Gp6500 Owners Manual

The National Electric Code requires that the frame and externally conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper groundingof the unit. For that purpose, connecting a No.

10 AWG (American Wire Gauge) stranded copper wire to the grounding lug and to an earth driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with a local electrician for grounding requirements in the area. How often should I start/operate my generator between outages? Most portable generators do not charge their batteries when running. Two Generac GP models, the 15,000 and the 17,500 and all electric start XP models charge their batteries while operating. Generac electric start generators, except those two GP models come with an external charger.

Generac Gp6500e Owners Manual Pdf

The customer should charge the battery at least once a month for 24-48 hours in preparation for usage. If the battery is dead, most of the portables have a recoil backup (pull start). 2017 honda rancher repair manual.

In emergency situations, the customer can charge the battery by plugging the charger cord into the receptacle on the generator while it is running. This is not recommended for typical operation.